Close-circuit', square-type cooling
tower |
| |
| |
| |
 |
| |
 |
MXC - 'Cross-flow' type |
| |
| |
| |
 |
MCC - 'Counter-flow'
type |
| |
| |
| |
 |
| |
 |
MXC-Z. AS & ASS
(Low noise & ultra low noise models) |
| |
| |
| |
 |
MCC.AS & ASS
(Low noise & ultra low noise models) |
|
|
|
 |
| |
 |
Compact in design, space-saving, &
light weight. Combination of a new type of heat exchanger & sprinkler
system, has improved the performance in heat exchanging. |
| |
| |
| |
 |
An improved heat exchanger was developed
with inclined spiral pipe provided with three-dimensional gradient
to improve drainage. This new development (which is US & Japanese
patent pending), is adopted in all models of the MXC-Z & MCC series. |
| |
| |
| |
 |
Increased durability. The coil used for
the cooling water is made of seamless deoxidised copper tubes, which
is superb characteristic against corrosion. Main steel components
of the tower are hot-dipped galvanised, while other parts are made
of either FRP or PVC material which assure long life & durability.
Sprinkler pumps used are suitable for outdoor installation. |
| |
| |
| |
 |
Low running & operating cost. With
a 'bell-mouth' contour designed fan casing, equipped with a high performance
low noise fan, which is specially designed for cooling tower application,
and combined with a newly developed high efficient heat exchanger,
enable the fan motor to be of lower power, thus saving energy and
as a result, in effectively reducing the operating cost. |
| |
| |
| |
 |
Low noise operation. Both 'low noise' &
'super low noise' models are available in both the MXC-Z & MCC
series to suit the environment noise requirement. |
| |
| |
| |
 |
Easy maintenance. Most movable parts are
positioned outside of the tower. The sprinkler system is structurally
self-cleaning. Each section of the multistage heat exchanger is detachable
and can be taken out easily for cleaning. |
| |
| |
| |
 |
Both MXC-Z & MCC series are delivered
in semi-assembled , therefore assembly time at site is greatly reduced.
|
| |
| |
| |
| |
 |
| |
 |
Most suitable for applications
when cooling tower is to operate in a polluted or dusty environment,
which may contaminate the circulating cooling water. In the case of
the close-circuit cooling tower, since the circulating water is completely
enclosed, it does not come into contact with the atmosphere.
when the heat exchanger (e.g. in the chiller) is experiencing
constant clogging or corrosion (due to contamination of circulating
cooling water).
when elimination of maintenance of the heat exchanger is desired.
when in the case of application of individual air-conditioning
system, protectin from damages to series of condensers is desired. |
| |
| |
| |
 |
Electronic industry |
| |
| |
| |
 |
Central air-conditioning systems |
| |
| |
| |
 |
Machine or process cooling for industrial
applications |